Equipment brand

Epiroc Equipment Air Conditioning and HVAC Repairs

Independent HVAC maintenance for Epiroc drill rigs and underground mining equipment.

CALL 069 268 0988

Epiroc equipment climate control

Rig cabs rely on pressurisation and multi-stage filtration to keep drill dust out of the operator station. Cabin pressure verification and short filter intervals are the core of effective maintenance. Independent repair and maintenance services for equipment equipped with these HVAC systems. Not an authorised dealer and not affiliated with the manufacturer.

Diagnostic process

  • Operator interview and fault confirmation with the machine running under load
  • Visual inspection of condenser, belts, hoses, wiring and cabin filters
  • High and low side pressure testing against the manufacturer's specification
  • Electronic leak detection, dye tracing or nitrogen pressure testing where required
  • Electrical fault finding on clutches, relays, pressure switches and control modules
  • Written findings, parts list and repair recommendation before work proceeds

Repair approach

  • Correct recovery of refrigerant before any component is opened
  • Compressor, condenser, evaporator, drier, valve, blower and harness repairs or replacement
  • System flushing and drier replacement after contamination or compressor failure
  • Vacuum, leak hold test, charge by weight and oil balance to specification
  • Function test across the full temperature range with cabin outlet readings recorded

Preventative maintenance recommendations

Scheduled condenser cleaning, cabin and pressurisation filter replacement, belt and clutch inspection, pressure checks and electrical inspection at fixed service intervals reduce the chance of unplanned cabin cooling failures during production hours.

Frequently asked questions

Epiroc equipment HVAC support

Speak to a heavy-equipment HVAC technician about diagnostics, repairs, regassing or a fleet maintenance programme.